ICF-1180I Series

Home  >   MOXA  >   Industrial Edge Connectivity  >  
Serial Converters  >   Fieldbus-to-Fiber Converters

Industrial PROFIBUS-to-fiber converters

Product Feature

  • Fiber-cable test function validates fiber communication
  • Auto baudrate detection and data speed of up to 12 Mbps
  • PROFIBUS fail-safe prevents corrupted datagrams in functioning segments
  • Fiber inverse feature
  • Warnings and alerts by relay output
  • 2 kV galvanic isolation protection
  • Dual power inputs for redundancy (Reverse power protection)
  • Extends PROFIBUS transmission distance up to 45 km
  • Wide-temperature model available for -40 to 75°C environments
  • Supports Fiber Signal Intensity Diagnosis

Introduction

The ICF-1180I industrial PROFIBUS-to-fiber converters are used to convert PROFIBUS signals from copper to optical fiber. The converters are used to extend serial transmission up to 4 km (multi-mode fiber) or up to 45 km (single-mode fiber). The ICF-1180I provides 2 kV isolation protection for the PROFIBUS system and dual power inputs to ensure that your PROFIBUS device will perform uninterrupted.

 

Fiber Cable Test Function

Fiber-optic cables are usually deployed for long-distance communication. To ensure proper communication across the fiber-optic cables, engineers use fiber sensors. A fiber cable test function through DIP switch adjustments helps ICF-11801 converters eliminate the need to rely on fiber-optic sensors.

This function not only detects fiber communication abnormalities but also validates the format of the received packet. It can also determine which side (Tx or Rx) is causing the problem.

 

PROFIBUS Fail-Safe

When the PROFIBUS device malfunctions or the serial interface fails, it will generate electrical noise, resulting in bus failure. Traditional media converters will let the noise signal pass through the fiber and on to the other converter. This will disrupt data transmissions between the two buses and eventually communication ceases across the entire system. When this occurs, the engineer will not be able to easily locate the failed device because the entire PROFIBUS network is down. To avoid this situation, the ICF-1180I was designed to detect and recognize noise signals. If the bus fails on one side, the noise signal will not propagate through the ICF-1180I and affect additional bus segments. In addition, the ICF-1180I will also trigger an alarm notification to the field engineer on the location of the failure.
 

Auto/Manual Baudrate Settings

The ICF-1180I Series simply converts the signal back and forth between PROFIBUS and fiber. The ICF-1180I Series works under baudrates between 9.6 kbps to 12 Mbps. Engineers do not need to know the baudrate of the connected PROFIBUS device.

The ICF-1180I Series can automatically detect the baudrate of the PROFIBUS device and apply this baudrate directly. This is an extremely convenient feature. If necessary, baudrates can be set to a fixed value via DIP switches.

 

Fiber Inverse Function

The ICF-1180I provides a fiber inverse function to choose fiber-optic light ON or light OFF when sending logic signal ‘1’. For default settings, fiber-optic is light OFF when sending logic signal ‘1’; in Fiber Inverse mode, fiber-optic is light ON when sending logic signal ‘1’.

This feature provides greater compatibility when the ICF-1180I converter is integrated with PROFIBUS converters of other manufacturers. Please refer to third-party user manuals when using this feature.

 

Fiber Link Monitor

The ICF-1180I converters provide a fiber link monitor function to detect the communication errors on either the fiber side or PROFIBUS side. Once there is an error in communication, the corresponding LED will turn red, and the relay alarm will be activated.

 

Fiber Signal Intensity Diagnosis

In some circumstances, you may need to measure the reception level of the fiber-optic port with a voltmeter, which can be connected while the device is operating (doing so will not affect data transmission). The measurement can be taken with a voltmeter and read on a PLC that uses floating high impedance analog inputs, which allow you to do the following:

  • Record the incoming optical power for later measurement (e.g., to indicate aging or damage).
  • Carry out a good/bad test (limit value).

Serial Interface

ConnectorICF-1180I-M-ST: Multi-mode ST connector
ICF-1180I-M-ST-T: Multi-mode ST connector
ICF-1180I-S-ST: Single-mode ST connector
ICF-1180I-S-ST-T: Single-mode ST connector
Optical FiberRead more

PROFIBUS Interface

Industrial ProtocolsPROFIBUS DP
No. of Ports1
ConnectorDB9 female
Baudrate9600 bps to 12 Mbps
Isolation2 kV (built-in)
SignalsPROFIBUS D+, PROFIBUS D-, RTS, Signal Common, 5V

Power Parameters

Input Current269 mA @ 12 to 48 VDC
Input Voltage12 to 48 VDC
No. of Power Inputs2
Overload Current ProtectionSupported
Power ConnectorTerminal block (for DC models)
Power Consumption269 mA @ 12 to 48 VDC

Physical Characteristics

HousingMetal
IP RatingIP30
Dimensions30.3 x 115 x 70 mm (1.19 x 4.53 x 2.76 in)
Weight180 g (0.39 lb)
InstallationDIN-rail mounting (with optional kit), Wall mounting

Environmental Limits

Operating TemperatureStandard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
0 to 60°C (32 to 140°F)
-40 to 75°C (-40 to 167°F)
Storage Temperature (package
included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)

Standards and Certifications

EMCEN 55032/24
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 0.5 kV
IEC 61000-4-5 Surge: Power: 0.5 kV
IEC 61000-4-6 CS: 3 V
IEC 61000-4-8 PFMF
Environmental TestingIEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-3
Hazardous LocationsATEX, Class I Division 2, IECEx
SafetyEN 60950-1, IEC 60950-1
VibrationIEC 60068-2-6

MTBF

Time1,722,769 hrs
StandardsTelcordia (Bellcore), GB

Warranty

Warranty Period5 years
DetailsSee www.moxa.com/warranty
Name Type Version Release Date
Datasheet for ICF-1180I Series Datasheet V1.1 21 May 2020

Notice: Undefined variable: rs5 in /opt/lampp/htdocs/english/productview.php on line 609

Notice: Trying to get property 'tab_ap' of non-object in /opt/lampp/htdocs/english/productview.php on line 609


Notice: Undefined variable: title_ap in /opt/lampp/htdocs/english/productview.php on line 614


Notice: Undefined variable: detail_ap in /opt/lampp/htdocs/english/productview.php on line 615

PT AUTOMATION (THAILAND) CO.,LTD.

Monday - Friday : office hours 9.00 AM – 6.00 PM

EN
TH