Login   |  
Notice: Undefined index: basket in /opt/lampp/htdocs/english/menutop.php on line 14
(0)   |  

TEL. & FAX +66(0)2-020-3301

ICF-1150 Series

Home  >   MOXA  >   Industrial Edge Connectivity  >  
Serial Converters  >   Serial-to-Fiber Converters

Industrial RS-232/422/485 to fiber converters

Product Feature

  • 3-way communication: RS-232, RS-422/485, and fiber
  • Rotary switch to change the pull high/low resistor value
  • Extends RS-232/422/485 transmission up to 40 km with single-mode or 5 km with multi-mode
  • -40 to 85°C wide-temperature range models available
  • C1D2, ATEX, and IECEx certified for harsh industrial environments

Introduction

The ICF-1150 serial-to-fiber converters transfer RS-232/RS-422/RS-485 signals to optical fiber ports to enhance transmission distance. When an ICF-1150 device receives data from any serial port, it sends the data through the optical fiber ports. These products not only support single-mode and multi-mode fiber for different transmission distances, models with isolation protection are also available to enhance noise immunity. The ICF-1150 products feature Three-Way Communication and a Rotary Switch for setting the pull high/low resistor for onsite installation.

 

Three-Way Communication

The ICF-1150 Series supports 2 serial ports, with a DB9 connector for RS-232 communication and a removable terminal block for RS-422 or RS-485 communication. The 3 ports (2 serial ports and one fiber port) are completely independent. When an ICF-1150 converter receives data from any one port, it will send the data through the other 2 ports. For example, once the ICF-1150 converter receives a command from the remote master through the fiber port, it will convert the signal and send the command through the RS-232 and RS-422/485 ports at the same time. If the user is monitoring a system running on an RS-485 network, there is no need to use an additional RS-232 to RS-485 converter to connect the laptop computer’s serial port to the RS-485 bus.

 

Rotary Switch for Setting the Pull High/Low Resistor

The RS-485 interface supports multidrop or daisy-chain connections, which system engineers will use to connect serial devices such as meters, RTUs, and readers, together on the same bus. Since the number of serial devices on the same bus will cause the impedance of the data line to increase, the ICF-1150 allows users to tune the pull high/low resistor. Just rotate the switch to the appropriate value without removing the ICF-1150 from the DIN rail.

Serial Interface

No. of Ports2
Serial StandardsRS-232, RS-422, RS-485
Baudrate50 bps to 921.6 kbps (supports non-standard baudrates)
Flow ControlADDC® (automatic data direction control) for RS-485
ConnectorDB9 male for RS-232 interface
5-pin terminal block for RS-422/485 interface
Fiber ports for RS-232/422/485 interface
Isolation2 kV (I models)
Optical FiberRead more
Pull High/Low Resistor for RS-485150 kilo-ohm, 10 kilo-ohm, 4.7 kilo-ohm, 3.3 kilo-ohm, 1 kilo-ohm, 909 ohm, 822 ohm,
770 ohm, 500 ohm, 485 ohm
RS-485 Data Direction ControlADDC® (automatic data direction control)
Terminator for RS-485N/A, 120 ohms, 120 kilo-ohms

Serial Signals

RS-232TxD, RxD, GND
RS-422Tx+, Tx-, Rx+, Rx-, GND
RS-485-4wTx+, Tx-, Rx+, Rx-, GND
RS-485-2wData+, Data-, GND

Power Parameters

Input CurrentICF-1150 Series: 264 mA @ 12 to 48 VDC
ICF-1150I Series: 300 mA @ 12 to 48 VDC
Input Voltage12 to 48 VDC
No. of Power Inputs1
Overload Current ProtectionSupported
Power ConnectorTerminal block
Power ConsumptionICF-1150 Series: 264 mA @ 12 to 48 VDC
ICF-1150I Series: 300 mA @ 12 to 48 VDC

Physical Characteristics

HousingMetal
IP RatingIP30
Dimensions30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in)
Weight330 g (0.73 lb)
InstallationDIN-rail mounting

Environmental Limits

Operating TemperatureStandard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature (package
included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)

Standards and Certifications

EMCEN 55032/24
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
Environmental TestingIEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-3
SafetyEN 60950-1, IEC 60950-1
VibrationIEC 60068-2-6
Hazardous Locations
Standard models: UL/cUL Class I Division 2 Groups A/B/C/D
-IEX models: UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2, IECEx

MTBF

Time792,085 hrs
StandardsTelcordia (Bellcore), GB

Warranty

Warranty Period5 years
DetailsSee www.moxa.com/warranty
Name Type Version Release Date
Datasheet for ICF-1150 Series Datasheet V1.4 21 May 2020

Notice: Undefined variable: rs5 in /opt/lampp/htdocs/english/productview.php on line 609

Notice: Trying to get property 'tab_ap' of non-object in /opt/lampp/htdocs/english/productview.php on line 609


Notice: Undefined variable: title_ap in /opt/lampp/htdocs/english/productview.php on line 614


Notice: Undefined variable: detail_ap in /opt/lampp/htdocs/english/productview.php on line 615

PT AUTOMATION (THAILAND) CO.,LTD.

Monday - Friday : office hours 9.00 AM – 6.00 PM

EN
TH